1793 |
ANIMATE_DUAL |
04/21/94 |
Unlike the AVS module, "animated integer", this animator co-routine keeps up with the range of the values available. It also allows the user to set a delta value for going forward (positive) or backward (negative). Additionally, the user can advance by single steps through data or continuously. When the end of the range is reached, the animator will wrap around the end of the range to the opposite end by delta. A second set of variables allows the synchronous control of two viewing windows. Output from the animator will cease for "Pause Seconds" # after each previous output. The MCNC Environmental Programs Group has created this module as part of a suite of AVS demo modules, networks, and sample data sets to demonstrate the functionality of its visualization prototype for an Environmental Decision Support System (EDSS). You can download these modules individually from the IAC using anonymous ftp to the appropriate directories /avs_modules at avs.ncsc.org. If you would like to download the entire suite of modules, networks, and sample datasets at the same time, the IAC recommends that you use anonymous ftp to grab the following file from avs.ncsc.org ftp/avs/Data/avs_dataMCNC_Env_Pgms/MCNC_Env_Pgms.tar.Z This contains all source code to all local and remote modules, as well as all of the sample datasets, networks, documentation, installation, and usage notes. |
| Author: | Kathy Pearson, MCNC Environmental Programs |
| Version: | 1.000 |
| Language: | C |
| Path: | source/data_input/ANIMATE_DUAL/ |
|
|
|
ANIMATE DUAL -- control 1 or 2 animations
ANIMATE DUAL -- control 1 or 2 animations
Name
ANIMATE DUAL -- control 1 or 2 animations
Author
Kathy Pearson, MCNC, kathyp@mcnc.org, (919) 248-9240
Summary
Name ANIMATE DUAL
Type data_input
Inputs none
Outputs output_integer_1 (int)
output_integer_2 (int)
Parameters Name Type Default Min Max
---- ---- ------- --- ---
Current Value 1 int 0 -1000000 1000000
Min Value 1 int 0 -1000000 1000000
Max Value 1 int 0 -1000000 1000000
Delta 1 int 1 -100 100
Current Value 2 int 0 -1000000 1000000
Min Value 2 int 0 -1000000 1000000
Max Value 2 int 0 -1000000 1000000
Delta 2 int 1 -100 100
Go toggle 0 0 1
One Step toggle 0 0 1
Pause Seconds int 0 0 10
Description
Unlike the AVS module, "animated integer", this animator co-routine keeps up
with the range of the values available. It also allows the user to set a
delta value for going forward (positive) or backward (negative). Additionally,
the user can advance by single steps through data or continuously. When
the end of the range is reached, the animator will wrap around the end of
the range to the opposite end by delta. A second set of variables allows
the synchronous control of two viewing windows. Output from the animator will
cease for "Pause Seconds" # after each previous output.
For connection to an AVS reader module to control record number updates to
effect animation, output_integer_1 should be wired to an integer port visible
Input
parameter on the reader. The reader module should output number of
hours and current hour, and these should be wired to the ANIMATE DUAL input
ports "Max Value 1" and "Current Value 1", respectively, for a first window.
For a seconds window, these should be wired to the ANIMATE DUAL "Max Value 2"
and "Current Value 2" input ports.
For better coordination between the reader and the animator, perhaps a more
ideal arrangement would be to make the reader have 3 record values (current,
min, and max) to match those of the animator.
INPUTS
(none)
Outputs
output_integer_1 animator #1 output
output_integer_2 animator #2 output
Parameters
Current Value 1 the current element # for animation sequence #1
Min Value 1 the minimum element # for animation sequence #1
Max Value 1 the maximum element # for animation sequence #1
Delta 1 the element increment for animation sequence #1
Current Value 2 the current element # for animation sequence #2
Min Value 2 the minimum element # for animation sequence #2
Max Value 2 the maximum element # for animation sequence #2
Delta 2 the element increment for animation sequence #2
Go toggle begin animation
One Step toggle stop animation after a single set of outputs
Pause Seconds # seconds to pause between sets of output
Example
Related modules
Limitations
See also
(MCNC Visualization Plan) 11/93
-------------------------------------------------------------------------
The MCNC Environmental Programs Group has created this module as part of a
suite of AVS demo modules, networks, and sample data sets to demonstrate
the functionality of its visualization prototype for an Environmental
Decision Support System (EDSS). This system provides a unified method of
analysis and visualization for data output from different environmental air
quality models. Remotely, standard output files from the following models
can be read into AVS:
ROM (Regional Oxidant Model)
RADM (Regional Acid Deposition Model), low res and high res
RADM (Regional Acid Depostion Model) Emissions, low res
UAM (Urban Airshed Model, regulatory version)
UAM (Urban Airshed Model, AREAL research version)
UAM Wind (Urban Airshed Model, regulatory version)
MCNC ALPHA-Prototype netCDF files
Alternatively, xdr portable binary AVS fields can be created from these
data types and accessed directly from the local workstation.
You can download these modules individually from the IAC using anonymous
ftp to the appropriate directories /avs_modules at avs.ncsc.org.
If you would like to download the entire suite of modules, networks, and
sample datasets at the same time, the IAC recommends that you use
anonymous ftp to grab the following file from avs.ncsc.org -
/sample_data/avs_data/MCNC_Env_Pgms/MCNC_Env_Pgms.tar.Z
This contains all source code to all local and remote modules, as well as
all of the sample datasets, networks, documentation, installation, and
usage notes.
-------------------------------------------------------------------------
|
|